Can a heat pump handle winter here
Your winter here is long and it gets properly cold. Heat runs nine months a year, September through May, and the overnight low averages 16°F across December, January and February. About 160 nights a year drop to freezing or below, more than half of the nights the heat is even on. About 10 nights a year reach 0°F or below.
A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to keep up. Both of those marks sit well above your 16°F average low, which means on a typical winter night here, and on every one of those 160 nights at or below freezing, a standard heat pump is working below both thresholds.
That does not mean a heat pump leaves you cold. A unit built to the ENERGY STAR Cold Climate spec has to prove it can still make 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its 47°F capacity at that same temperature, checked by outside testing. In a two-winter field test of prototype cold-climate units in real homes, backup heat only covered a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. So the spec is not a marketing number. It is the difference between a heat pump that struggles here and one built for exactly this kind of winter.
If you are buying a standard heat pump, Berkshire County winters will ask it to lean on backup heat on a lot of nights. If you are buying a cold-climate model, the facts here say it can do the job on its own most of the time, down to real cold.