Will a heat pump keep up with winter here
Your winters average 21°F overnight across December, January and February, and the heat runs here from October through May, about eight months. A standard heat pump starts falling short of its rated heat output below 40°F, and below about 35°F it often needs backup heat to make up the difference. Essex County sits below both marks most nights all winter. Of the roughly 245 nights the heat runs here, about 130 are at or below freezing, over half of them, and on every one of those nights a standard heat pump is working below the point where its output and its efficiency both drop.
That does not rule out a heat pump. It rules out a standard one. A heat pump built to the ENERGY STAR Cold Climate spec has to prove, under third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. Essex County only sees 0°F or below about 4 nights a year, a small slice of the 130 freezing nights. A field test of prototype cold-climate heat pumps running in occupied homes over two winters found backup heat covering only a small share of the load between 0°F and 35°F, and the units running on backup alone was rare even above 0°F.
So the question is not whether a heat pump can work in this county. It is which heat pump. A standard model bought on price will lean on backup heat most of the winter here. A cold-climate model is built for exactly these nights, and the testing behind that label is what tells you it will hold up on the four nights a year that reach 0°F, not just the 130 that reach freezing.