Cold is the normal case here, not the exception
Winters in Hampshire County decide this choice. The overnight low averages 18°F across December, January and February, and about 150 nights a year dip to freezing or below. That is over half the nights in the eight months your heat runs. A standard heat pump starts falling short of its rated heat output below 40°F, and often leans on backup heat below about 35°F. Here, every single one of those 150 freezing nights falls below both marks.
That does not mean a heat pump cannot heat your house. It means it is working below its best range on most winter nights, not just a handful of cold snaps. If you go with a heat pump, the one to look at is the ENERGY STAR Cold Climate kind. To earn that label it has to prove, under third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. A standard heat pump isn't tested or built to do that.
Backup heat does not mean it is running constantly once it gets cold. In a two-winter field test of prototype cold-climate heat pumps in occupied homes, backup heat covered only a small share of the total heat between 0°F and 35°F, and the system ran on backup alone only rarely, even above 0°F. Hampshire County only sees about 9 nights a year at 0°F or below. The deep cold that would lean hardest on backup heat is the smaller part of your winter here, not the bulk of it.